Industrial hardware for global sourcing teamstony.buy@gmail.com
Pipe Hangers & Support Hardware

Clevis Hangers

Clevis Hangers for industrial distribution, project purchasing and OEM supply, with material, finish and documentation agreed per quotation.

Quick Answer

What buyers should know about Clevis Hangers.

Pipe support hardware carries, guides or restrains piping while accommodating installation and service conditions. Pipe size, insulation, temperature, movement, load and support spacing must be evaluated together.

Built to Drawing

One product family, configured around your requirement.

Most parts in this range are made or adapted for a drawing, sample, mating interface and order program. The image on this page represents the product family; final geometry, material, finish, inspection and marking are confirmed in the quotation.

  1. DefineDrawing, sample, interface and quantity.
  2. EngineerMaterial, process, tolerances and finish.
  3. VerifyCritical dimensions and agreed records.
  4. RepeatApproved packaging and revision control.
Four-stage custom hardware workflow from requirement review to repeat delivery
Technical illustration — representative workflow, not a fixed product model or customer project.
Product-Specific Engineering Brief

Clevis hangers suspend horizontal pipe while allowing vertical adjustment.

An adjustable clevis hanger uses a U-shaped clevis, cross bolt and upper strap connected to threaded rod. MSS SP-58 identifies this arrangement as Type 1. Select it from the supported pipe's operating weight, insulation, contents, test load, temperature movement and the capacity of every component up to the building attachment.

Material and selection

Carbon steel with electrozinc, pre-galvanized or hot-dip galvanized finish is common; stainless steel may suit selected corrosive environments. Finish alone does not establish capacity. Specify pipe OD, insulation thickness and shield, rod size, design load, service temperature and corrosion exposure. The clevis must cradle the pipe or insulation shield without crushing insulation, binding movement or placing the cross bolt against the pipe.

Installation and FAQ

Attach rod only to an approved structural point, assemble the correct clevis and cross bolt, seat the pipe centrally and adjust elevation without consuming required thread engagement. Lock adjustment hardware and inspect alignment after filling or testing the line. Can a clevis hanger provide seismic bracing? Not by itself. Can it support sloped pipe? Only if the approved support layout prevents sliding and side loading. Can rod size be chosen from pipe size alone? No; calculate the supported load and check MSS/manufacturer limits.

Galvanized clevis hanger suspended from threaded rod around a steel pipe
Read the suspended connection as one assembly.The threaded connection, clevis body and lower pin carry the load through different interfaces.Confirm pipe outside diameter, rod connection and movement allowance for the selected hanger.Check finish compatibility with the pipe, environment and adjacent support hardware.

Research sources: MSS SP-58 Type 1 and selection/installation provisions; Sioux Chief MSS SP-58 clevis-hanger bulletin. Capacities are per exact product data.

Material & Standards Reference

Specification starting points for Clevis Hangers.

Clevis Hangers belongs to the pipe support component category. Material names, standards and coating descriptions below help buyers structure an RFQ; they are not a declaration that every offered configuration complies. Grade, edition, inspection level and acceptance criteria belong on the controlled drawing or purchase specification. (industry reference data, final values per drawing/quotation)

Material route

Carbon steel, stainless steel, malleable iron, ductile iron and elastomer-lined constructions are common depending on the support function. Base material, coating and liner must be compatible with one another and with the pipe and environment.

Mechanical performance

Use the tensile strength, yield or proof strength, elongation, hardness, impact and heat-treatment requirements published for the selected material grade. Relevant properties differ by product form and test-piece basis. They describe material quality, not the capacity of the finished Clevis Hangers; final suitability depends on geometry, interfaces, manufacturing condition and verification.

Finish and records

Specify plain, zinc-coated, hot-dip galvanized, painted, passivated or another compatible finish by a recognized coating specification where applicable. Define preparation, appearance, restricted substances, repair rules, packaging and required inspection documents instead of relying on a color photograph.

ReferenceStandard nameHow to use it
MSS SP-58Pipe Hangers and Supports — Materials, Design, Manufacture, Selection, Application, and InstallationUse as an RFQ reference only when applicable; edition, scope and acceptance evidence must be agreed.
MSS SP-69Pipe Hangers and Supports — Selection and ApplicationUse as an RFQ reference only when applicable; edition, scope and acceptance evidence must be agreed.
ASTM A36/A36MCarbon Structural SteelUse as an RFQ reference only when applicable; edition, scope and acceptance evidence must be agreed.
ASTM B633Electrodeposited zinc coatings on iron and steelUse as an RFQ reference only when applicable; edition, scope and acceptance evidence must be agreed.
ISO 1461Hot dip galvanized coatings on fabricated iron and steel articlesUse as an RFQ reference only when applicable; edition, scope and acceptance evidence must be agreed.
EN 10204Metallic products — Types of inspection documentsUse as an RFQ reference only when applicable; edition, scope and acceptance evidence must be agreed.

Specification caution: naming a material, coating or dimensional standard does not create a product rating, approval, certification or warranty. Any required capacity, pressure class, temperature limit, listing or test must be confirmed for the exact quoted part. (industry reference data, final values per drawing/quotation)

Selection Decision Guide

Turn the application into a checkable purchasing specification.

Selection for Clevis Hangers should begin with pipe outside diameter, insulation, support function, movement, attachment interface, corrosion environment and complete assembly design. Keep required facts separate from supplier proposals so reviewers can see what is mandatory and what remains open. (industry reference data, final values per drawing/quotation)

DecisionInformation to provideWhy it matters
Interface and geometryDrawing, nominal or actual dimensions, tolerances, mating components, clearances, orientation and accessible assembly space.Prevents selection from a family name or image and allows the complete connection to be checked.
Service conditionFunction, direction of forces, movement, vibration, indoor or outdoor exposure, moisture, chemicals and maintenance access.Guides material, finish, locking, restraint and inspection choices without inventing an unverified rating.
Compliance routeDestination market, governing code, required standard edition, customer specification, marking and third-party approval needs.Separates a generally suitable design from a configuration qualified for a regulated project.
Supply and qualityQuantity, release pattern, drawing revision, critical characteristics, sampling, traceability, packaging and documents.Aligns manufacturing and inspection with the commercial requirement and repeat-order control.

Ask the supplier to identify exclusions and assumptions in the quotation. Compare offers against the same revision and requirement list; a lower price is not comparable if material, coating, inspection, packaging or documentation scope differs. Final commercial values remain per quotation.

Installation & Use

General receiving, fitting and inspection workflow.

(industry reference data, final values per drawing/quotation)

01

Receive and identify

Match labels, part identity, material or heat references where required, quantity and documents to the purchase order. Quarantine mixed, damaged, corroded or unidentifiable pieces instead of releasing them to installation.

02

Check the interface

Verify the actual mating dimensions, thread or connection form, contact surfaces, orientation and working clearance. Clean protective debris without removing functional coatings or altering critical edges.

03

Assemble correctly

Confirm pipe size, support location, insulation and movement allowances before fitting. Keep rods plumb where required, seat the pipe evenly, avoid point contact and over-compression of liners, install locking hardware, and inspect the complete load path from structure to pipe. Any torque, clearance, sealant, gasket, lubrication or locking value must come from the approved instruction for the exact product.

04

Inspect and maintain

Record completion where the quality plan requires it. Inspect for seating, alignment, locking, leakage where relevant, coating damage and interference. Establish service checks from the system risk assessment and replace parts that fail the applicable acceptance criteria.

  • Do not infer capacity or suitability from appearance, catalog category, material name or a similar product.
  • Do not mix bodies, pins, nuts, fasteners, seals, liners or accessories unless compatibility is documented.
  • Do not repair, weld, heat, bend, grind, drill or reuse a component unless the controlled procedure permits it.
  • Escalate any mismatch between the site condition and approved drawing before the assembly is put into service.
Related & Compatible Products

Compare the complete function before choosing an alternative.

Compare clamps, clevis hangers, riser clamps, U-bolts, brackets and support assemblies by whether they restrain, guide, suspend or support the pipe and whether thermal movement must remain free. Compatibility includes the mating dimensions, material couple, coating, fastener or seal system, installation method, inspection basis and service environment. (industry reference data, final values per drawing/quotation)

Standard configuration

Best when an established size, connection and documented product scope match the application. Confirm the exact designation and do not extend published information to another variant.

Adjacent product family

Useful when the required function or interface differs. Review the whole assembly, because an alternative component can move forces, change clearances or require different accessories and installation controls.

Made-to-drawing option

Consider when geometry, material, marking, finish or packaging cannot be met by a standard item. Freeze the drawing, validation plan and change-control route before repeat production.

Application FAQ

Additional questions about Clevis Hangers.

(industry reference data, final values per drawing/quotation)

Does a cited ASTM, ISO, EN, ASME or MSS standard prove product compliance?

No. The reference helps define material, dimensions, coating, test method or use practice within its own scope. Compliance requires the applicable edition, product configuration, acceptance criteria and agreed evidence. A standards list on a general webpage is not a certificate.

How should mechanical properties be specified?

Name the material standard, grade, product form, heat-treatment condition where relevant, required inspection document and any supplementary tests. Use the values in the governing published standard rather than copying an isolated number. Finished-product capacity or performance still requires design and verification for the exact geometry.

What information prevents the most quotation delays?

Provide a legible drawing or complete dimensional description, application and mating parts, material and finish, quantity and release schedule, destination market, required standards, critical characteristics, marking, packaging and document needs. Identify any requirement that cannot change.

Can material or finish be substituted?

Only after technical and commercial review. A substitute can change strength, ductility, corrosion behavior, friction, thread fit, coating thickness, galvanic compatibility, manufacturing route and inspection evidence. Record an approved deviation before production.

How are final ratings or service limits obtained?

Request verified data for the exact part number, revision, material, assembly orientation and mating components. The quotation or approved technical package should state the applicable basis. This page intentionally supplies no invented load, pressure, temperature or price values.

What should incoming inspection cover?

Check identity, quantity, revision, obvious damage, corrosion protection, critical dimensions and the documents named in the purchase order. Sampling, gauges and acceptance limits should be agreed in the quality plan. Keep nonconforming items segregated pending disposition.

When is a custom version appropriate?

A custom route is appropriate when the standard interface, geometry, material, finish, marking, inspection or packaging cannot satisfy the application. Provide annual demand and validation expectations so tooling, casting, forging, stamping, machining or fabrication options can be reviewed.

What controls should apply to repeat orders?

Reference the approved drawing revision and agreed specification, preserve approved samples or inspection records as appropriate, and require notification before material, process, tooling or supplier changes that affect critical characteristics. Reconfirm requirements after a design or application change.

Clevis Hangers product family reference
Product Overview

Specify the part around the real application.

Clevis Hangers for industrial distribution, project purchasing and OEM supply, with material, finish and documentation agreed per quotation.

Product familyPipe Hangers & Support Hardware
Supply routeStandard configuration or made to requirement
Materials & finishCarbon steel, cast iron, stainless steel and elastomer-cushioned options with zinc, galvanized or specified finishes.
ApplicationsPlumbing, HVAC, fire protection, industrial process piping and mechanical plant installations.
DocumentationInspection, traceability and shipment records agreed per quotation
Selection Guide

Four checks before requesting a quote.

01

Pipe OD and insulation

Define this requirement on the drawing or RFQ so the offered configuration can be checked.

02

Support function and movement

Define this requirement on the drawing or RFQ so the offered configuration can be checked.

03

Temperature and environment

Define this requirement on the drawing or RFQ so the offered configuration can be checked.

04

Rod, bracket and structural interface

Define this requirement on the drawing or RFQ so the offered configuration can be checked.

Engineering & Supply

From requirement review to repeat delivery.

Application review

We review geometry, interfaces, service environment and critical characteristics before confirming the supply route.

Manufacturing route

Casting, forging, machining, stamping, fabrication and finishing are matched to part geometry and repeat volume.

Quality planning

Material checks, dimensional inspection, surface review and agreed records are defined around the quoted part.

Standards note: referenced standards, ratings and certifications vary by product and market. State every required standard in the RFQ; no rating should be inferred from a category image or general description.

Frequently Asked Questions

Clevis Hangers FAQ

What are Clevis Hangers?

Clevis Hangers are part of the pipe hangers & support hardware family. Pipe support hardware carries, guides or restrains piping while accommodating installation and service conditions. Pipe size, insulation, temperature, movement, load and support spacing must be evaluated together.

Which information is needed to quote Clevis Hangers?

Provide a drawing, dimensions or reference part number, plus material, finish, quantity, application, destination market and documentation needs.

Which materials and finishes are available?

Carbon steel, cast iron, stainless steel and elastomer-cushioned options with zinc, galvanized or specified finishes. Availability is confirmed against the exact geometry, quantity and service conditions.

How should this product be selected?

Check pipe od and insulation, support function and movement, temperature and environment, rod, bracket and structural interface. Final suitability must be verified against the quoted product data and application.

Can Clevis Hangers be made to drawing?

Yes. Drawing-based development can cover geometry, material, machining, finish, marking, packing and inspection requirements, subject to manufacturing review.

Can certificates or inspection records be supplied?

Required inspection and shipment documents should be listed in the RFQ. Applicable records are agreed before order confirmation.

Request pricing for Clevis Hangers.

Send Your Requirement →